Specifications

Battery/ rechargeable battery

battery LR6 AA 1,5V x4

Current source

0...24mA

Current source accuracy

±(0,025% + 1 digit)

DC current measuring accuracy

±(0.025% + 1 digit)

DC current measuring range

0...24mA

DC voltage measuring accuracy

±(0.02% + 2 digit)

DC voltage measuring range

0...100mV

DC voltage measuring range

0...30V

Dimensions

200x96x47mm

Illumination

Yes

Kind of calibrator

Voltage

Kind of calibrator

Current

Kind of calibrator

RTD

Kind of calibrator

thermocouple

Kind of display used

LCD

Manufacturer

FLUKE

Measurement

resistance

Measurement

DC voltage

Measurement

DC current

Measuring instrument features

tests in 25% steps and at 100% of signal

Measuring instrument features

automatic execution of tests by means of "Auto-Step" and "Auto-Ramp" functions that enable to obtain sawtooth waveform and changed by steps signal

Measuring instrument features

measures and sources current signals

Measuring instrument features

measures and sources RTD signals

Measuring instrument features

measures and sources thermocouple signals

Measuring instrument features

measures and sources voltage signals

Measuring instrument features

operates with 7 types of RTDs: Pt100 (385), Pt200, Pt500, Pt1000 (385), Pt100 (3916), Pt100 (3926), Ni120 (672)

Measuring instrument features

operates with thermocouple types: J, K, T, E, R, S, B, L, N, U

Measuring instrument features

settings memory

Measuring instrument features

supplies 24V loop with simultaneous current measurement

Power Supply

battery LR6 AA 1,5V x4

Resistance measuring accuracy

±(0.1%+1Ω)

Resistance measuring range

10mΩ...400Ω

Resistance measuring range

1.5kΩ

Resistance measuring range

3.2kΩ

Standard equipment

crocodile clips FLK-AC72

Standard equipment

FLK-TL75 test leads

Standard equipment

manufacturers calibration certificate

Standard equipment

set of test leads with alligator clips

Type of device

Calibrator

Voltage source

0...10V

Voltage source accuracy

±(0,02% + 2 digits)

Ω simulation

15...3200Ω