Final Unit Price is calculated at the checkout is inclusive of Indian Customs Duty, International Freight, Insurance, Handling Fees and other charges

FLK-393-IRR-PVLEAD

FLK-393-IRR-PVLEAD

Clamp Multimeters & Accessories Fluke 393 FC Clamp,IRR1 Irradiance Meter,MC4 Test Leads Bundle

Mfr Part #

FLK-393-IRR-PVLEAD

Life Cycle

New Product

HSN Code

90303338

Top notch industry experts are waiting to help you. Get a free quote today!

Suppliers

DigiKey Electronics

DigiKey Electronics

Stock : 0

Packaging Type

Bulk

VendorPart#

1986-FLK-393-IRR-PVLEAD-ND

Factory Lead Time

0 Days

Ware House

US Warehouse

Date Code

Within 2 years

Min: 1
Mult: 1

0

Mouser Electronics

Mouser Electronics

* Not available for purchase by distributors.

RESTRICTED*


Packaging Type

-

VendorPart#

676-FLK393IRR-PVLEAD

Factory Lead Time

61 Days

Ware House

US Warehouse

HTS Code

9030333800

Date Code

Within 2 years

Min: 1
Mult: 1

0

TME

TME

Stock : 1

Packaging Type

-

VendorPart#

FLK-393-IRR-PVLEAD

Ware House

Poland Warehouse

Date Code

Min: 1
Mult: 1

Specifications

AC current measuring accuracy

±(2% + 5 digits)

AC current measuring range

100mA...999.9A

AC voltage measuring accuracy

±(1% + 5 digits)

AC voltage measuring range

600V

AC voltage measuring range

1kV

Battery/ rechargeable battery

battery LR6 AA 1,5V x2

Capacitance measuring accuracy

±(1% + 5 digits)

Capacitance measuring range

1000µF

Capacitance measuring range

0.1...100µF

CF crest factor

3k @ 1.1kA

CF crest factor

1.42k @ 2.5kA

CF crest factor

2.5k @ 600A

Conform to the norm

EN 61010 600V CAT IV

Conform to the norm

EN 61010 1500V CAT III

Continuity test

<30Ω

Continuity test

acoustic indication

DC current measuring accuracy

±(2% + 5 digits)

DC current measuring range

100mA...999.9A

DC voltage measuring accuracy

±(1% + 5 digits)

DC voltage measuring range

600V

DC voltage measuring range

1.5kV

Dimensions

281x84x49mm

Equipment Part Numbers

-

Equipment Type

Current Meter (Clamp/Probe)

Frequency measuring accuracy

±(0,5% + 5 digits)

Frequency measuring range

5...500Hz

Illumination

Yes

Interface

Bluetooth

Kind of display used

LCD

Kind of meter

pincers type

Kind of meter

digital

Manufacturer

FLUKE

Max. diameter of measured cable

34mm

Measurement

peak current

Measurement

inrush current

Measurement

frequency

Measurement

DC voltage

Measurement

DC current

Measurement

current (with current clamps)

Measurement

continuity

Measurement

capacitance

Measurement

AC voltage

Measurement

AC current

Measurement

resistance

Measuring instrument features

AUTO HOLD

Measuring instrument features

automatic power-off

Measuring instrument features

flexible current probe up to 2500A

Measuring instrument features

HOLD function

Measuring instrument features

MIN/MAX/AVG function

Measuring instrument features

polarization indicator

Pollution degree

2

Power Supply

battery LR6 AA 1,5V x2

Resistance measuring accuracy

±(1% + 5 digits)

Resistance measuring range

600Ω

Resistance measuring range

6kΩ

Resistance measuring range

60kΩ

Set Type

Electrical Maintenance and Test

Software

Fluke Connect

Standard equipment

test leads MC4

Standard equipment

test leads ( 2pcs.)

Standard equipment

magnetic hanging strap

Standard equipment

iFlex2500-18 - current clamp

Standard equipment

FLK-IRR1-SOL meter

Standard equipment

Case

True effective value measurement

True RMS

Type of meter

Multifunction

Weight with battery

520g